FocalSV enables target region–based structural variant assembly and refinement using single-molecule long-read sequencing data

Table 4.

Large deletions and insertions (≥50 bp) calling performance across three ONT data sets

Library Metric FocalSV (target) FocalSV (auto) PAV SVIM-asm Dipcall cuteSV SVIM Sniffles2
DEL ONT_L1 Precision 91.89% 92.25% 91.10% 90.86% 86.48% 91.32% 90.88% 91.60%
Recall 93.90% 93.44% 92.78% 93.90% 90.72% 92.78% 93.00% 92.44%
F1 92.89% 92.84% 91.94% 92.35% 88.55% 92.05% 91.93% 92.02%
GT concordance 98.94% 98.75% 98.74% 98.78% 92.64% 99.08% 98.30% 99.19%
ONT_L2 Precision 92.03% 92.27% 90.88% 91.05% 84.66% 85.56% 86.35% 79.67%
Recall 93.97% 93.34% 89.04% 93.71% 88.61% 92.40% 92.54% 92.35%
F1 92.99% 92.80% 89.95% 92.36% 86.59% 88.84% 89.34% 85.54%
GT concordance 99.12% 98.59% 98.72% 98.73% 90.18% 98.87% 98.03% 99.03%
ONT_L3 Precision 92.27% 91.59% 90.96% 91.03% 85.39% 88.84% 88.84% 88.06%
Recall 93.61% 92.13% 90.89% 93.71% 89.14% 92.42% 92.81% 92.42%
F1 92.93% 91.86% 90.92% 92.35% 87.22% 90.59% 90.78% 90.18%
GT concordance 99.12% 98.71% 98.74% 98.81% 91.06% 99.11% 98.46% 99.32%
Overall Precision 92.06% 92.04% 90.98% 90.98% 85.51% 88.57% 88.69% 86.44%
Recall 93.83% 92.97% 90.90% 93.77% 89.49% 92.53% 92.78% 92.40%
F1 92.94% 92.50% 90.94% 92.35% 87.45% 90.49% 90.68% 89.25%
GT concordance 99.06% 98.68% 98.73% 98.77% 91.29% 99.02% 98.26% 99.18%
INS ONT_L1 Precision 86.38% 90.18% 86.03% 85.28% 65.47% 90.32% 82.60% 89.00%
Recall 92.84% 92.01% 92.71% 93.33% 89.45% 91.55% 88.45% 91.14%
F1 89.50% 91.09% 89.25% 89.12% 75.60% 90.93% 85.42% 90.06%
GT concordance 98.14% 98.87% 97.22% 98.19% 63.74% 98.88% 85.70% 95.95%
ONT_L2 Precision 86.24% 89.82% 84.72% 85.06% 63.83% 89.86% 81.65% 88.40%
Recall 93.60% 92.05% 89.24% 92.90% 86.80% 90.57% 86.86% 90.19%
F1 89.77% 90.92% 86.92% 88.80% 73.56% 90.21% 84.17% 89.29%
GT concordance 98.30% 98.89% 97.18% 97.92% 59.25% 98.49% 82.52% 95.28%
ONT_L3 Precision 86.81% 89.93% 84.78% 84.48% 64.42% 90.24% 81.55% 88.65%
Recall 92.99% 91.50% 90.72% 92.67% 86.99% 91.06% 88.87% 90.70%
F1 89.80% 90.71% 87.65% 88.39% 74.03% 90.65% 85.05% 89.67%
GT concordance 98.37% 98.28% 97.10% 98.10% 60.58% 98.96% 86.96% 95.64%
Overall Precision 86.48% 89.98% 85.18% 84.94% 64.57% 90.14% 81.93% 88.68%
Recall 93.14% 91.85% 90.89% 92.97% 87.75% 91.06% 88.06% 90.68%
F1 89.69% 90.91% 87.94% 88.77% 74.40% 90.60% 84.88% 89.67%
GT concordance 98.27% 98.68% 97.17% 98.07% 61.19% 98.78% 85.06% 95.62%
  • The table presents recall, precision, F1 score (in %), and genotype accuracy (measured by genotype concordance) for all benchmarked SV callers. The highest scores for recall, precision, F1, and genotype accuracy are highlighted in bold. Additionally, the overall average performance for each SV type and library is summarized at the bottom of the table. Benchmarking was conducted using Truvari with the following parameter settings: p = 0.5, P = 0.5, r = 500, and O = 0.01.

This Article

  1. Genome Res. 35: 2252-2272

Preprint Server