Table 3.
FP–TDI Assay with Synthetic Templates Using Different Dye Terminators
| Templates | BFL–ddA (mP) | TMR–ddC (mP) | ROX–ddG (mP) | BTR–ddU (mP) |
| CF508–48A | 38 | 43 | 77 | 174 |
| 37 | 53 | 73 | 175 | |
| 31 | 36 | 78 | 174 | |
| 35 | 49 | 82 | 170 | |
| CF508–48C | 20 | 50 | 214 | 32 |
| 19 | 37 | 209 | 27 | |
| 20 | 56 | 215 | 25 | |
| 14 | 38 | 207 | 26 | |
| CF508–48G | 23 | 247 | 84 | 23 |
| 24 | 266 | 80 | 30 | |
| 22 | 253 | 75 | 23 | |
| 15 | 262 | 74 | 21 | |
| CF508–48T | 113 | 52 | 81 | 32 |
| 106 | 41 | 68 | 39 | |
| 108 | 59 | 81 | 30 | |
| 103 | 32 | 76 | 28 | |
| Avg. ctrl. | 25 | 46 | 86 | 28 |
| s.d.Ctrl. | 8.2 | 8.8 | 4.6 | 5.0 |
| Avg. net chg. | 83 | 211 | 134 | 145 |
-
Positive reactions are in boldface type.
-
↵FP measurements for BFL were made with excitation at 480 nm and emission at 520 nm; for TMR the excitation was 535 nm and emission was 590 nm; for BTR the excitation was 591 nm and emission was 635 nm; for ROX the excitation was 580 nm and emission was 620 nm.
-
↵Net change over average of control.