Rapid Detection of Deletion, Insertion, and Substitution Mutations via Heteroduplex Analysis Using Capillary- and Microchip-Based Electrophoresis

(Downloading may take up to 30 seconds. If the slide opens in your browser, select File -> Save As to save it.)

Click on image to view larger version.

Figure 4.
Figure 4.

Detection sensitivity with capillary electrophoresis-based heteroduplex analysis. Panels (A) and (B) show the heteroduplex analysis results with the 6174delT and 5677insAmutants. Wild-type DNA template and the mutated DNA template were mixed together and coamplified by PCR for analysis by CE-LIF. The mixed percentages of the mutated DNA template were specified in the figure. The separation buffer was 2.5% HEC containing 10% glycerol in 1 × TBE. Other CE conditions were as in Fig. 1.